Engineering / Stair regulations in Europe

Engineering · Reference

Stair regulations in Europe

Rail heights, openings, step sizes, handrails and landings – the numbers we design to in 12 countries, side by side, with links to the official texts.

Every country writes its own stair rules, and the differences matter in steel. A balustrade that passes in Oslo can fail in Riga, and an open-riser stair that is fine in Warsaw needs closing up in Stockholm.

This page is our working reference. We keep it because we design, fabricate and install stairs across these markets – and every project starts by checking the local rules.

At a glance

All values in millimetres. H = height of the flight.

CountryRail height on stairsMax opening in guardingGap between open treadsHandrail extensionSteps before a landingMain regulation
Norway900100—300H > 3300TEK17 §§ 12-14, 12-15 + DiBK veiledning
Sweden900ᵃ100100300ᵃ18ᵃBoverket BFS 2024:9
Denmark80089ᵃ—300ᵃ—BR18 §§ 57–61
Finland900–1000100100300ᵃ—YM 1007/2017
England (UK)90010010030012–16Approved Document K + BS 5395-2
Scotland (UK)840–900100100—16Technical Handbook 2022: Domestic 4.3–4.4
Latvia1100120—300—LBN 200-21 (MK Nr. 693)
Lithuania900ᵇ120ᵇ——17ᵇSTR 2.02.01:2004 / STR 2.02.09
Estonia900ᵇ100ᵇ——18EVS 837-1 + SiM nr 17
Poland900 / 1100120 / 200—30017Warunki techniczne §§ 68–71, 298
Germany900120120300ᵃ18DIN 18065 + LBO / MBO § 38
Netherlands850100—300H ≤ 4000Besluit bouwwerken leefomgeving (Bbl)

ᵃ guidance or standard, not a binding regulation · ᵇ from secondary sources – verify · — no numeric requirement found

Key differences

  • Openings: 100 mm in Norway, Sweden, Finland, the UK and the Netherlands; 120 mm in Latvia, Lithuania, Poland and Germany. Denmark tests with an 89 mm wedge.
  • Rail height on stairs: usually 840–900 mm, but 1100 mm in Latvia and in Polish apartment and public buildings.
  • Open risers: Sweden, Finland and the UK cap the gap between treads at 100 mm, Germany at 120 mm.
  • Accessibility: handrails continue about 300 mm past the first and last step, and the first and last step is marked in contrast – Norway asks for a luminance contrast of 0.8, Swedish guidance for 0.40 NCS.

Questions and answers

Which country has the highest stair rail requirement?

Latvia: rails on stairs and landings must be at least 1100 mm high, measured from the step nosing. Poland asks for 1100 mm in apartment and public buildings. Most other countries require 840–900 mm on the stair itself.

What is the 100 mm sphere rule?

Openings in guarding must not let a 100 mm sphere or cube through, so a small child cannot get its head stuck. Norway, Sweden, Finland, the UK and the Netherlands use 100 mm; Latvia, Lithuania, Poland and Germany use 120 mm; Denmark uses an 89 × 140 mm wedge test.

Are open-riser stairs allowed?

Yes, but several countries limit the gap between treads: 100 mm in Sweden, Finland and the UK (with a tread overlap of 15–16 mm in the UK) and 120 mm in Germany. In the UK, buildings other than dwellings should not have open risers.

How many steps can a flight have before a landing?

Germany: at most 18 risers (DIN 18065). Poland and Lithuania: 17. Estonia: 18 on escape stairs. The UK: 12–16 in buildings other than dwellings. Norway sets a height instead (a landing above 3.3 m) and the Netherlands limits one flight to 4 m. The Swedish standard SS 91 42 21 splits flights above 18 steps.

Who checks a stair against these rules?

The designer and the contractor are responsible, and the local building authority inspects. We check the rules of the country where the stair is installed at the start of every project and design the steel, glass and timber to them.

How to use this page

This is a summary for designers, not legal advice. Rules change, some values are guidance or standards rather than law, and local authorities interpret them. Always confirm against the current official text linked on each country page.

Need a stair that passes first time?

Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.