Engineering · Reference
Stair regulations in Sweden
The numbers that matter when you design a stair or balustrade in Sweden, from Boverket BFS 2024:9.
· Source status: Official regulation texts
Requirements
| Rail height on stairs | Not fixed in BFS 2024:9 (risk-based). Former BBR guidance: ≥ 900 mm; ≥ 1100 mm where the storey height exceeds 3.0 m |
|---|---|
| Rail height on landings and balconies | Not fixed. Former BBR guidance: ≥ 1100 mm (landings outside the dwelling, balconies) |
| Max opening in guarding | Vertical openings ≤ 100 mm where young children may be; horizontal openings must not be 110–230 mm |
| Gap between open treads | ≤ 100 mm (requirement, ch. 2 § 6) |
| Climbability | The lowest 800 mm must be hard to climb (where young children may be) |
| Rise | No fixed value (risk assessment) |
| Going | No value in BFS. Former BBR guidance: ≥ 250 mm indoors, ≥ 300 mm outdoors |
| Headroom | ≥ 2000 mm |
| Handrail | Both sides (one side where two are unnecessary); height not fixed in BFS (former BBR: 900 mm) |
| Handrail extension | Former BBR guidance: ≥ 300 mm past the top and bottom nosing. BFS 2024:9: support at the start and end of the movement, no value |
| Landings | No value in BFS. Standard SS 91 42 21 (dwellings): split the flight above 18 steps |
| Marking of first and last step | Requirement (ch. 2 § 8): start and end of every flight clearly marked in contrast. Boverket guidance: lightness contrast ≥ 0.40 NCS on the bottom tread and the top landing edge – for people with low vision |
| Notes | Gap under the stair rail to the nosings ≤ 50 mm; to a landing ≤ 100 mm. BBR stopped applying on 1 July 2026. |
Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.
Questions and answers
How high must a stair balustrade be in Sweden?
Rail height on stairs: Not fixed in BFS 2024:9 (risk-based). Former BBR guidance: ≥ 900 mm; ≥ 1100 mm where the storey height exceeds 3.0 m. Rail height on landings and balconies: Not fixed. Former BBR guidance: ≥ 1100 mm (landings outside the dwelling, balconies).
What is the maximum opening in stair guarding in Sweden?
Max opening in guarding: Vertical openings ≤ 100 mm where young children may be; horizontal openings must not be 110–230 mm. Climbability: The lowest 800 mm must be hard to climb (where young children may be).
When does a stair need a landing in Sweden?
Landings: No value in BFS. Standard SS 91 42 21 (dwellings): split the flight above 18 steps.
Other countries
Need a stair that passes first time?
Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.