Requirements

Rail height on stairs≥ 800 mm; ≥ 1200 mm where the stairwell gap exceeds 300 mm
Rail height on landings and balconiesLandings ≥ 900 mm; generally ≥ 1000 mm
Max opening in guardingGuidance: a wedge of 89 × 140 mm (DS/EN 1176-1) must not pass; in practice about 80 mm or less
ClimbabilityChildren must not be able to climb the guarding or get trapped (no numeric rule)
Rise≤ 180 mm
Going≥ 280 mm (≥ 250 mm in residential buildings)
Stair width≥ 1000 mm
Headroom≥ 2100 mm
HandrailBoth sides, about 800 mm, continuous past landings, horizontal ends
Handrail extensionRecommended ≥ 300 mm past the start and end (Bolius guidance, not BR18)
Marking of first and last stepOutdoor access: change of surface in colour and texture 900 mm before the stair; tread edges in a contrast colour
Spiral and curved stairsSpindle and winding stairs: going ≥ 200 mm
NotesInternal stairs in detached single-family houses are outside BR18 chapter 2.

Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.

Questions and answers

How high must a stair balustrade be in Denmark?

Rail height on stairs: ≥ 800 mm; ≥ 1200 mm where the stairwell gap exceeds 300 mm. Rail height on landings and balconies: Landings ≥ 900 mm; generally ≥ 1000 mm.

What is the maximum opening in stair guarding in Denmark?

Max opening in guarding: Guidance: a wedge of 89 × 140 mm (DS/EN 1176-1) must not pass; in practice about 80 mm or less. Climbability: Children must not be able to climb the guarding or get trapped (no numeric rule).

Need a stair that passes first time?

Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.