Engineering / Stair regulations in Europe / Norway

Engineering · Reference

Stair regulations in Norway

The numbers that matter when you design a stair or balustrade in Norway, from TEK17 §§ 12-14, 12-15 + DiBK veiledning.

· Source status: Official regulation texts

Requirements

Rail height on stairs≥ 900 mm
Rail height on landings and balconies≥ 1000 mm; ≥ 1200 mm where the drop exceeds 10 m
Max opening in guardingMax 100 mm up to 750 mm height (guarding over 1000 mm: up to 250 mm below the top)
ClimbabilityGuarding must prevent climbing (vertical balusters)
RiseNo fixed value – an even rise, set by the stair formula
Going≥ 250 mm indoors, ≥ 280 mm outdoors (on the walking line)
Step formula2R + G = 620 ± 20 mm
Stair width900 mm (800 mm inside a dwelling); main stair serving several dwellings 1100 mm; universal design 1200 mm; curved stairs +100 mm
Headroom2100 mm (2000 mm inside a dwelling)
HandrailBoth sides, top at 800–900 mm; main stairs: 800 mm or two rails at 700 + 900 mm
Handrail extension300 mm past the top and bottom step, rounded end (main stairs, universal design)
LandingsRequired where the rise exceeds 3.3 m; a fall-stopping landing ≥ 1800 mm long; depth ≥ stair width
Marking of first and last stepMain stairs: nosing strip across the full width, luminance contrast ≥ 0.8, depth ≤ 40 mm; universal design: warning field before the top step
Spiral and curved stairsCurved stairs: going ≥ 150 mm on the inner walking line (300 mm from the inner handrail); escape routes ≥ 200 mm
NotesMax 50 mm between guarding and the building edge. DiBK consulted on changes to § 12-14 in 2024.

Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.

Questions and answers

How high must a stair balustrade be in Norway?

Rail height on stairs: ≥ 900 mm. Rail height on landings and balconies: ≥ 1000 mm; ≥ 1200 mm where the drop exceeds 10 m.

What is the maximum opening in stair guarding in Norway?

Max opening in guarding: Max 100 mm up to 750 mm height (guarding over 1000 mm: up to 250 mm below the top). Climbability: Guarding must prevent climbing (vertical balusters).

When does a stair need a landing in Norway?

Landings: Required where the rise exceeds 3.3 m; a fall-stopping landing ≥ 1800 mm long; depth ≥ stair width.

Need a stair that passes first time?

Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.