Engineering · Reference
Stair regulations in England (UK)
The numbers that matter when you design a stair or balustrade in England (UK), from Approved Document K + BS 5395-2.
· Source status: Secondary sources – verify against the official text
Requirements
| Rail height on stairs | 900 mm above the pitch line |
|---|---|
| Rail height on landings and balconies | Dwellings: 900 mm on internal landings, 1100 mm on external balconies. Other buildings: 1100 mm |
| Max opening in guarding | A 100 mm sphere must not pass (where children under five may be) |
| Gap between open treads | A 100 mm sphere must not pass; treads overlap ≥ 16 mm |
| Climbability | Guarding should not be easily climbable |
| Rise | Private 150–220 mm; utility 150–190 mm; general access 150–170 mm |
| Going | Private 220–300 mm; others 250–400 mm |
| Step formula | 2R + G = 550–700 mm; private stairs ≤ 42° |
| Stair width | Not set in Approved Document K (see Approved Documents B and M) |
| Headroom | 2000 mm (loft conversions 1900 / 1800 mm) |
| Handrail | 900–1000 mm; one side below 1000 mm width, both sides at 1000 mm and wider |
| Handrail extension | ≥ 300 mm beyond the top and bottom of the flight |
| Landings | Non-dwellings: ≤ 16 risers (utility), ≤ 12 (general access, exceptionally 16). Dwellings: more than 36 risers in a row need a change of direction of ≥ 30° |
| Marking of first and last step | Common areas of flats: contrasting nosing 50–65 mm on the tread and 30–55 mm on the riser |
| Spiral and curved stairs | Design to BS 5395-2; tapered treads ≥ 50 mm at the narrow end |
| Notes | The Building Safety Regulator is reviewing Part K (call for evidence open until 28 December 2026); current guidance stays in force. Scotland has its own rules – see below. |
Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.
Questions and answers
How high must a stair balustrade be in England (UK)?
Rail height on stairs: 900 mm above the pitch line. Rail height on landings and balconies: Dwellings: 900 mm on internal landings, 1100 mm on external balconies. Other buildings: 1100 mm.
What is the maximum opening in stair guarding in England (UK)?
Max opening in guarding: A 100 mm sphere must not pass (where children under five may be). Climbability: Guarding should not be easily climbable.
When does a stair need a landing in England (UK)?
Landings: Non-dwellings: ≤ 16 risers (utility), ≤ 12 (general access, exceptionally 16). Dwellings: more than 36 risers in a row need a change of direction of ≥ 30°.
Other countries
Need a stair that passes first time?
Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.