Requirements

Rail height on stairs900 mm above the pitch line
Rail height on landings and balconiesDwellings: 900 mm on internal landings, 1100 mm on external balconies. Other buildings: 1100 mm
Max opening in guardingA 100 mm sphere must not pass (where children under five may be)
Gap between open treadsA 100 mm sphere must not pass; treads overlap ≥ 16 mm
ClimbabilityGuarding should not be easily climbable
RisePrivate 150–220 mm; utility 150–190 mm; general access 150–170 mm
GoingPrivate 220–300 mm; others 250–400 mm
Step formula2R + G = 550–700 mm; private stairs ≤ 42°
Stair widthNot set in Approved Document K (see Approved Documents B and M)
Headroom2000 mm (loft conversions 1900 / 1800 mm)
Handrail900–1000 mm; one side below 1000 mm width, both sides at 1000 mm and wider
Handrail extension≥ 300 mm beyond the top and bottom of the flight
LandingsNon-dwellings: ≤ 16 risers (utility), ≤ 12 (general access, exceptionally 16). Dwellings: more than 36 risers in a row need a change of direction of ≥ 30°
Marking of first and last stepCommon areas of flats: contrasting nosing 50–65 mm on the tread and 30–55 mm on the riser
Spiral and curved stairsDesign to BS 5395-2; tapered treads ≥ 50 mm at the narrow end
NotesThe Building Safety Regulator is reviewing Part K (call for evidence open until 28 December 2026); current guidance stays in force. Scotland has its own rules – see below.

Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.

Questions and answers

How high must a stair balustrade be in England (UK)?

Rail height on stairs: 900 mm above the pitch line. Rail height on landings and balconies: Dwellings: 900 mm on internal landings, 1100 mm on external balconies. Other buildings: 1100 mm.

What is the maximum opening in stair guarding in England (UK)?

Max opening in guarding: A 100 mm sphere must not pass (where children under five may be). Climbability: Guarding should not be easily climbable.

When does a stair need a landing in England (UK)?

Landings: Non-dwellings: ≤ 16 risers (utility), ≤ 12 (general access, exceptionally 16). Dwellings: more than 36 risers in a row need a change of direction of ≥ 30°.