Engineering · Reference
Stair regulations in Germany
The numbers that matter when you design a stair or balustrade in Germany, from DIN 18065 + LBO / MBO § 38.
· Source status: Official texts and published guidance
Requirements
| Rail height on stairs | 900 mm (drop 1–12 m); 1100 mm (drop over 12 m) |
|---|---|
| Rail height on landings and balconies | The same; 1000 mm in workplaces (e.g. Hesse) |
| Max opening in guarding | ≤ 120 mm in at least one direction (e.g. Berlin § 38); Baden-Württemberg: horizontal gaps ≤ 20 mm up to 600 mm height |
| Gap between open treads | ≤ 120 mm (DIN 18065 for non-residential buildings; some LBO also for housing) |
| Climbability | Climbing must be made difficult (vertical bars, a closed panel up to 700 mm, etc.) |
| Rise | Buildings with up to 2 dwellings 140–200 mm; other buildings 140–190 mm |
| Going | Up to 2 dwellings 230–370 mm; other buildings 260–370 mm |
| Stair width | Up to 2 dwellings 800 mm; other buildings 1000 mm |
| Headroom | 2000 mm |
| Handrail extension | ≥ 300 mm horizontal (DIN 18040, barrier-free) |
| Landings | After at most 18 risers (DIN 18065; not in buildings with up to 2 dwellings) |
| Marking of first and last step | DIN 18040 (barrier-free): 40–50 mm strip at the tread nosing, 10–20 mm on the riser; at least the first and last step |
| Spiral and curved stairs | Winders: going ≥ 50 mm at the inner boundary (dwellings) |
| Notes | Side gap to the wall or guarding ≤ 60 mm. Each federal state has its own building code (LBO) – check the one that applies. |
Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.
Questions and answers
How high must a stair balustrade be in Germany?
Rail height on stairs: 900 mm (drop 1–12 m); 1100 mm (drop over 12 m). Rail height on landings and balconies: The same; 1000 mm in workplaces (e.g. Hesse).
What is the maximum opening in stair guarding in Germany?
Max opening in guarding: ≤ 120 mm in at least one direction (e.g. Berlin § 38); Baden-Württemberg: horizontal gaps ≤ 20 mm up to 600 mm height. Climbability: Climbing must be made difficult (vertical bars, a closed panel up to 700 mm, etc.).
When does a stair need a landing in Germany?
Landings: After at most 18 risers (DIN 18065; not in buildings with up to 2 dwellings).
Other countries
Need a stair that passes first time?
Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.