Engineering · Reference
Stair regulations in Finland
The numbers that matter when you design a stair or balustrade in Finland, from YM 1007/2017.
· Source status: Official regulation texts
Requirements
| Rail height on stairs | Inside a dwelling (drop under 3 m): ≥ 900 mm |
|---|---|
| Rail height on landings and balconies | 1000 mm (drop up to 6 m); 1200 mm (drop over 6 m); guarding required where the drop exceeds 500 mm |
| Max opening in guarding | Vertical members only: openings may pass a cube of at most 100 mm; other infill: at most 30 mm; horizontal slots ≤ 10 mm |
| Gap between open treads | At most a 100 mm cube may pass |
| Climbability | No horizontal elements in the protective part |
| Rise | Dwelling ≤ 190 mm; other main stairs ≤ 180 mm; public lobbies ≤ 160 mm; uncovered outdoor ≤ 130 mm |
| Going | Dwelling ≥ 250 mm; other ≥ 270 mm; public ≥ 300 mm; uncovered outdoor ≥ 390 mm |
| Stair width | Evacuation areas ≥ 850 mm |
| Headroom | 2100 mm; stairs (not exits) and dwelling stairs 1950 mm |
| Handrail | Both sides, full length; height not fixed |
| Handrail extension | Must continue past the start and end of the flight (§ 9); accessibility guidance: ≥ 300 mm |
| Landings | Guidance: a rest landing every 10–15 steps (City of Helsinki, not a regulation) |
| Marking of first and last step | Guidance: 20–40 mm dark-contrast strip on the tread edge (City of Helsinki) |
| Spiral and curved stairs | No separate provision |
| Notes | A protective part ≥ 700 mm high is needed where the drop exceeds 700 mm and children have access. Gap below the infill: at most a 50 mm cube; between handrail and infill: at most 200 mm. |
Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.
Questions and answers
How high must a stair balustrade be in Finland?
Rail height on stairs: Inside a dwelling (drop under 3 m): ≥ 900 mm. Rail height on landings and balconies: 1000 mm (drop up to 6 m); 1200 mm (drop over 6 m); guarding required where the drop exceeds 500 mm.
What is the maximum opening in stair guarding in Finland?
Max opening in guarding: Vertical members only: openings may pass a cube of at most 100 mm; other infill: at most 30 mm; horizontal slots ≤ 10 mm. Climbability: No horizontal elements in the protective part.
When does a stair need a landing in Finland?
Landings: Guidance: a rest landing every 10–15 steps (City of Helsinki, not a regulation).
Other countries
Need a stair that passes first time?
Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.