Engineering / Stair regulations in Europe / Estonia

Engineering · Reference

Stair regulations in Estonia

The numbers that matter when you design a stair or balustrade in Estonia, from EVS 837-1 + SiM nr 17.

· Source status: Secondary sources – verify against the official text

Requirements

Rail height on stairsIn practice ≥ 900 mm in dwellings (secondary source)
Max opening in guardingEVS 837-1: ≤ 100 mm (secondary source)
RiseEVS 837-1: dwellings 150–190 mm, public buildings 130–170 mm (secondary); draft accessibility rules ≤ 160 mm
GoingDraft accessibility rules: ≥ 270 mm indoors or covered, ≥ 400 mm uncovered outdoors; escape stairs ≥ 270 mm
Step formulaEVS 837-1: 2R + G = 600–640 mm (secondary)
HeadroomEscape routes ≥ 2100 mm
HandrailRequired on stairs with more than 3 steps
Landings3–18 steps per flight (escape stairs)
Spiral and curved stairsSpiral escape stair (use class III, schools): central opening ≥ 1000 mm, tread ≥ 150 mm
NotesEstonia has no single national stair regulation. The accessibility regulation was still a draft in 2025–2026.

Summary for designers, last checked November 2026. Always confirm against the current official text and with the local building authority.

Questions and answers

How high must a stair balustrade be in Estonia?

Rail height on stairs: In practice ≥ 900 mm in dwellings (secondary source).

What is the maximum opening in stair guarding in Estonia?

Max opening in guarding: EVS 837-1: ≤ 100 mm (secondary source).

When does a stair need a landing in Estonia?

Landings: 3–18 steps per flight (escape stairs).

Need a stair that passes first time?

Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.