Engineering · Reference
Spiral, helical and winder stairs
Tapered treads are measured differently. Where the walking line sits, how deep the tread must be on it and how narrow the inner end may get – country by country.
On a straight stair every tread has the same depth across its width. On a spiral, helical or winder stair the tread tapers: wide at the outside, narrow at the inside. So the rules do not ask for one depth. They fix a walking line at a set distance from the narrow side, set a minimum going on that line and often a minimum at the narrow end as well.
These are the rules we check first on every helical and spiral stair we engineer. Get them wrong and the stair fails inspection, however good the steel.
How tapered treads are measured (plan view)
- d – distance of the walking line from the narrow side (inner handrail, column or edge of the usable width)
- g – going measured on the walking line, between two nosings
- n – going at the narrow end of the tread
- w – clear width between handrails, or between column and handrail
Diagram for explanation only, not to scale. Each country defines d, g, n and w in its own way – see the table.
Four numbers to check
Walking line
The line people actually walk on, set at a fixed distance from the narrow side. The going is measured on it.
Going on the walking line
The tread depth on the walking line – usually the same minimum as on a straight stair, though some countries allow less on curved stairs.
Narrow end
The going at the inner end of the tread. It must still leave room for a foot.
Clear width
Measured between handrails, or between the column and the handrail. Tight spiral stairs often fail on width before they fail on going.
Country comparison
All values in millimetres. C = centre line of the flight; 270 = 270 mm from each side on flights 1 m or wider; B = usable width. Two values: dwellings / other buildings.
| Country | Walking line from the narrow side | Min going on the walking line | Min going at the narrow end | Min stair width | Rule |
|---|---|---|---|---|---|
| Norway | 300 | 150 | — | 900 (+100) | TEK17 § 12-14 |
| Sweden | — | 250ᵃ | — | — | BFS 2024:9 (BBR 8:232) |
| Denmark | — | 200 | — | 1000 | BR18 § 57 |
| Finland | — | — | — | 850 | YM 1007/2017 |
| England (UK) | C / 270 | 220 / 250 | 50 | 600–800ᵃ | ADK + BS 5395-2 |
| Scotland (UK) | C / 270 | 225 / 250 | 50 | 900 | Technical Handbook 4.3.9–4.3.10 |
| Latvia | — | — | — | — | LBN 200-21 |
| Lithuania | 400ᵇ | 250ᵇ | — | — | STR 2.02.01:2004 |
| Estonia | — | — | — | — | EVS 837-1 |
| Poland | 400ᵇ | 250ᵇ | — | 800 | WT § 68–69 |
| Germany | 20 % B | 230 / 260 | 50 / 100 | 800 / 1000 | DIN 18065 |
| Netherlands | 300 | 220 / 185 | 50 | 800 | Bbl art. 4.26 |
ᵃ guidance or standard, not a binding regulation · ᵇ from secondary sources – verify · — no numeric requirement found
What we have learned from building them
- Fix the walking line before you fix the diameter. The diameter follows from the going you need on the walking line, not the other way round.
- Check the narrow end and the clear width together: a larger column widens the narrow end but takes away clear width.
- Many buildings do not accept spiral or curved stairs as escape stairs. Check the fire rules before you design one as the only stair.
- A helical stair around an open eye gives more freedom than a spiral stair around a column: the inner edge can be set where the rules need it.
Questions and answers
What is the walking line on a spiral stair?
The line along which the going is measured. Countries place it differently: 300 mm from the inner handrail in Norway, at least 300 mm from both sides in the Netherlands, 400 mm from the inner handrail in Poland and Lithuania, and at the centre line (or 270 mm from each side on wide flights) in England and Scotland.
How narrow can a tapered tread be at the inner end?
England, Scotland and the Netherlands ask for at least 50 mm. Germany asks for 50 mm in dwellings with up to two flats and 100 mm in other buildings, measured at the inner edge of the usable width.
Can a spiral stair be the main stair of a house?
Often yes, if it meets the going and width rules on the walking line. In England, BS 5395-2 category B covers a spiral stair that is the main access to an upper floor of a dwelling (going about 190 mm at the centre, clear width 800 mm). Escape stairs in other buildings are a different matter – many countries do not accept spiral or curved stairs there.
What is the difference between spiral, helical and winder stairs?
A spiral stair turns around a central column, a helical stair around an open eye, and a winder stair has tapered treads only where it turns. The same rules for tapered treads apply to all three.
Full requirements per country
Main sources
- Norway: DiBK – TEK17 § 12-14
- Sweden: Boverket – trappor (BBR)
- Sweden: Boverket – bredd i utrymningsvägar
- Denmark: Bygningsreglementet – BR18 krav § 57
- Finland: Finlex – 1007/2017
- England (UK): GOV.UK – Approved Document K
- England (UK): Designing Buildings – spiral and helical stairs
- Scotland (UK): gov.scot – 4.3 Stairs and ramps (domestic)
- Latvia: likumi.lv – LBN 200-21
- Lithuania: e-seimas – STR 2.02.01:2004
- Estonia: EVS 837-1 kokkuvõte
- Poland: Inżynier Budownictwa – schody, wymagania
- Poland: § 68 szerokość schodów (lexlege.pl)
- Germany: Baunetz Wissen – Spindeltreppen
- Germany: Baunetz Wissen – Gehbereich
- Germany: DGUV – Treppen-Sonderbauformen
- Netherlands: Bbl artikel 4.26 – tabel 4.26
How to use this page
This is a summary for designers, not legal advice. Rules change, some values are guidance or standards rather than law, and local authorities interpret them. Always confirm against the current official text linked on each country page.
Need a stair that passes first time?
Send us your drawings. We check them against the local rules, engineer the stair and build it in our Riga workshop.